Meanwell LRS-200-5 LED Ngalih 5V 40A Power Supply
Fitur
- Range input AC sing bisa dipilih kanthi ngalih
- Tahan input lonjakan 300VAC sajrone 5 detik
- Proteksi: Sirkuit cendhak / Overload / Overvoltage /Luwih saka suhu
- Pendinginan kanthi konveksi udara bebas
- 1U low profile
- Tahan tes geter 5G
- Indikator LED kanggo daya
- Ora ana konsumsi daya mbukak <0.75W
- 100% tes burn-in beban penuh
- Suhu operasi dhuwur nganti 70 ℃
- Ketinggian operasi nganti 5000 meter (Cathetan.8)
- Efisiensi dhuwur, umur dawa lan linuwih
- garansi 3 taun
Aplikasi
- Mesin otomasi industri
- Sistem kontrol industri
- Peralatan mekanik lan listrik
- Instrumen elektronik, piranti utawa piranti
Model Encoding
Spesifikasi
MODEL | LRS-200-3.3 | LRS-200-4.2 | LRS-200-5 | LRS-200-12 | LRS-200-15 | LRS-200-24 | LRS-200-36 | LRS-200-48 | |
OUTPUT | VOLTAGE DC | 3.3V | 4.2V | 5V | 12V | 15V | 24V | 36V | 48V |
RATED SAIKI | 40A | 40A | 40A | 17A | 14A | 8.8A | 5.9A | 4.4A | |
RANGE SAIKI | 0 ~ 40A | 0 ~ 40A | 0 ~ 40A | 0 ~ 17A | 0 ~ 14A | 0 ~ 8.8A | 0 ~ 5.9A | 0 ~ 4.4A | |
DAYA RATED | 132W | 168W | 200W | 204W | 210W | 211.2W | 212.4W | 211.2W | |
RIPPLE & NOISE (maks.) Cathetan.2 | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
VOLTAGE ADJ.RANGE | 2.97 ~ 3.6V | 3.6 ~ 4.4V | 4.5 ~ 5.5V | 10.2 ~ 13.8V | 13.5 ~ 18V | 21.6 ~ 28.8V | 32.4 ~ 39.6V | 43.2 ~ 52.8V | |
TOLERANSI TEGANGAN Cathetan.3 | ± 3,0% | ± 4,0% | ± 3,0% | ± 1,5% | ± 1,0% | ± 1,0% | ± 1,0% | ± 1,0% | |
PERATURAN GARIS Cathetan.4 | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% | |
PERATURAN MOBAN Cathetan.5 | ± 2,5% | ± 2,5% | ± 2,0% | ± 1,0% | ± 0,5% | ± 0,5% | ± 0,5% | ± 0,5% | |
SETUP, MANGKAT WAKTU | 1300ms, 50ms/230VAC 1300ms,50ms/115VAC ing beban penuh | ||||||||
WAKTU TAHAN (Typ.) | 16ms/230VAC 12ms/115VAC ing beban penuh | ||||||||
INPUT | RANGE VOLTAGE | 90 ~ 132VAC / 180 ~ 264VAC kanthi ngalih 240 ~ 370VDC (ngaktifake 230VAC) | |||||||
RANGKA FREKUENSI | 47 ~ 63Hz | ||||||||
EFISIENSI (Typ.) | 83% | 86% | 87% | 87,5% | 88% | 89,5% | 89,5% | 90% | |
AC ARUS (Typ.) | 4A / 115VAC 2.2A / 230VAC | ||||||||
INRUSH ARUS (Typ.) | COLD STAR 60A / 115VAC 60A / 230VAC | ||||||||
KEBOCORAN SAIKI | <2mA / 240VAC | ||||||||
pangayoman | OVER LOAD | 110 ~ 140% daya output dirating | |||||||
3.3 ~ 36V mode Hiccup, pulih kanthi otomatis sawise kondisi fault dibusak.48V Pateni lan pasang voltase o/p, urip maneh kanggo pulih. | |||||||||
OVER VOLTAGE | 3.8 ~ 4.45V | 4.6 ~ 5.4V | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 18 ~ 21V | 28.8 ~ 33.6V | 41.4 ~ 46.8V | 55.2 ~ 64.8V | |
3.3 ~ 36V mode Hiccup, pulih kanthi otomatis sawise kondisi fault dibusak.48V Pateni lan pasang voltase o/p, urip maneh kanggo pulih. | |||||||||
SUHU | 3.3 ~ 36V mode Hiccup, pulih kanthi otomatis sawise kondisi fault dibusak.48V Pateni lan pasang voltase o/p, urip maneh kanggo pulih. | ||||||||
LINGKUNGAN | KERJA TEMP. | -25 ~ +70 ℃ (Deleng "Kurva Derating") | |||||||
AMBES KERJA | 20 ~ 90% RH non-kondensasi | ||||||||
TEMP., Asor | -40 ~ +85 ℃, 10 ~ 95% RH | ||||||||
TEMP.KOEFISIEN | ± 0,03% / ℃ (0 ~ 50 ℃) | ||||||||
GETERAN | 10 ~ 500Hz, 5G 10menit/1siklus, 60menit.saben sumbu X, Y, Z | ||||||||
KESELAMATAN | STANDAR KESELAMATAN | IEC/UL 62368-1, BSMI CNS14336-1, EAC TP TC 004, KC K60950-1 (mung kanggo LRS-200-12/24),BIS IS13252(Part1): 2010/IEC 60950-1: 2005, AS/NZS62368.1 disetujoni;Desain deleng BS EN/EN62368-1 | |||||||
NAHAN VOLTAGE | I/PO/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||||||||
RESISTANCE Isolasi | I/PO/P, I/P-FG, O/P-FG: 100M Ohm / 500VDC / 25 ℃ / 70% RH | ||||||||
EMISI EMC | Selaras karo BSMI CNS13438, EAC TP TC 020, KC KN32, KN35 (mung kanggo LRS-200-12/24) | ||||||||
IMMUNITY EMC | Selaras karo BS EN/EN55035, EAC TP TC 020, KC KN32, KN35 (mung kanggo LRS-200-12/24) | ||||||||
LAIN | MTBF | 2346.6K jam min.Telcordia SR-332 (Bellcore);279.4Khrs min.MIL-HDBK-217F (25 ℃) | |||||||
DIMENSI | 215 * 115 * 30mm (L * W * H) | ||||||||
KEMASAN | 0,66Kg;15pcs / 10.9Kg / 0.78CUFT | ||||||||
CATETAN | 1. Kabeh paramèter sing ora disebutake khusus diukur ing input 230VAC, beban dirating lan 25 ℃ suhu sekitar.2. Ripple & gangguan diukur ing 20MHz bandwidth kanthi nggunakake 12 "bengkong pasangan-kabel mungkasi karo 0.1uf & 47uf kapasitor podo.3. Toleransi : kalebu nyetel toleransi, angger baris lan angger-angger mbukak.4. Regulasi garis diukur saka garis kurang nganti garis dhuwur kanthi beban sing dirating. 5. Regulasi beban diukur saka 0% nganti 100% beban sing dirating. 6. Dawane wektu nyiyapake diukur ing wiwitan kadhemen.Ngaktifake / mateni sumber daya kanthi cepet bisa uga nambah wektu nyetel. 7. Kapabilitas beban puncak 150% dibangun nganti 1 detik kanggo 12 ~ 48V.LRS-200 bakal mlebu mode hiccup yen beban puncak dikirim luwih saka 1 detik lan bakal pulih yen diterusake menyang level saiki sing dirating (115VAC / 230VAC). 8. Suhu sekitar derating 5 ℃ / 1000m dibutuhake kanggo dhuwur operasi luwih saka 2000m (6500ft). 9. Sumber daya iki ora nyukupi syarat saiki harmonik sing digarisake dening BS EN / EN61000-3-2. Aja nggunakake sumber daya iki ing kahanan ing ngisor iki: a) piranti pungkasan digunakake ing Uni Eropa, lan b) piranti pungkasan disambungake menyang sumber listrik umum kanthi voltase nominal 220Vac utawa luwih gedhe, lan c) sumber daya yaiku: - diinstal ing piranti pungkasan karo daya input rata-rata utawa terus-terusan luwih saka 75W, utawa - kalebu bagean saka sistem cahya Pangecualian: Pasokan daya sing digunakake ing piranti pungkasan ing ngisor iki ora kudu netepi BS EN/EN61000-3-2 a) peralatan profesional kanthi total daya input sing dirating luwih saka 1000W; b) unsur pemanas sing dikontrol kanthi simetris kanthi daya dirating kurang saka utawa padha karo 200W. |